1.
Rev. bras. eng. biomed ; 26(1): 11-24, abr. 2010. ilus, tab, graf
Article in Portuguese | LILACS | ID: lil-570335

ABSTRACT

Este trabalho teve por objetivo o desenvolvimento e avaliação da eficácia de um protocolo de controle de qualidade de imagens geradas por equipamentos de ultrassom operando no modo B, que fosse de fácil implementação e que utilizasse um único objeto de testes. O protocolo proposto foi avaliado em 25 equipamentos de ultrassom utilizados em medicina obstétrica, ginecologia e clínica médica, selecionados em várias clínicas e hospitais de Curitiba, Brasil. Somente modelos de equipamentos que suportavam os três tipos padrões de transdutores (convexo, linear e endocavitário) foram incluídos nos testes. No entanto, em alguns dos equipamentos, nem todos os transdutores estavam disponíveis, totalizando 72 transdutores avaliados durante os testes. Um objeto de testes de uso geral foi utilizado para avaliar os seguintes parâmetros: resoluções laterais e axiais, profundidade de visualização e exatidão das distâncias medidas, entre outras. O protocolo foi implementado em duas partes: uma envolvendo a inspeção física do equipamento/monitor e outra para avaliação dos transdutores. Entre os resultados obtidos, pode-se destacar a efetividade e simplicidade do protocolo proposto, o qual é completamente baseado em um único objeto de testes. Considerando as normas e relatórios técnicos utilizados, para aproximadamente 86% dos transdutores avaliados, falhas foram detectadas em um ou mais indicadores de qualidade de imagem. Os resultados obtidos estão de acordo com outros estudos realizados no Brasil, mostrando que um grande número de equipamentos utilizados diariamente em clínicas e hospitais apresenta um ou mais parâmetros fora dos limites estabelecidos em normas técnicas, tornando difícil o diagnóstico médico e, consequentemente, submetendo o paciente a riscos.


This study aims the development of a quality control protocol of images generated by B-mode ultrasound equipment, being of simple implementation and making use of a single phantom, as well as the evaluation of the proposed protocol effectiveness. The proposed protocol was evaluated on 25 ultrasound equipment used in obstetric medicine, gynaecology and medical clinic, selected from several clinics and hospitals of Curitiba, Brazil. Only systems with three standard transducers (convex, linear and endocavitary types) should be selected, however for some units not all of them were available, thus a total of 72 transducers were tested. A general purpose phantom was used to evaluate the following parameters: lateral and axial resolution, deepness of visualization and accuracy between distances, among others. The protocol was implemented in two parts: one involving the physical inspection of the equipment/monitor and another for the transducers evaluation. Among the results obtained, one is highlighted by the effectiveness and simplicity of the proposed protocol, which is completely based on a single phantom. Considering the utilized standards and technical reports, for approximately 86% of the evaluated transducers, some kind of failure or problem was detected in one or more image quality indicators. The results, inaccordance to those obtained by other authors in Brazil, showed that agreat number of equipment used daily in clinics and hospitals present one or more parameters out of the standards, making the medical diagnosis difficult and consequently submitting the patient to risks.


Subject(s)
Equipment Failure Analysis/instrumentation , Equipment Failure Analysis/methods , Equipment Failure Analysis/standards , Diagnostic Techniques, Obstetrical and Gynecological/instrumentation , Diagnostic Techniques, Obstetrical and Gynecological/standards , Ultrasonography/instrumentation , Ultrasonography/standards , Quality Control , Equipment and Supplies, Hospital/standards , Diagnostic Errors/prevention & control , Equipment Failure , Reference Standards , Equipment Safety/instrumentation , Transducers/standards
SELECTION OF CITATIONS
SEARCH DETAIL